TY - JOUR
T1 - The effect of air permeability characteristics of protective garments on the induced physiological strain under exercise-heat stress
AU - Epstein, Yoram
AU - Heled, Yuval
AU - Ketko, Itay
AU - Muginshtein, Jeni
AU - Yanovich, Ran
AU - Druyan, Amit
AU - Moran, Daniel S.
PY - 2013/8
Y1 - 2013/8
N2 - Objectives:The high values of thermal resistance (Rct) and/or vapor resistance (Ret) of chemical protective clothing (CPC) induce a considerable thermal stress. The present study compared the physiological strain induced by CPCs and evaluates the relative importance of the fabrics' Rct, Ret, and air permeability in determining heat strain.Methods:Twelve young (20-30 years) healthy, heat-acclimated male subjects were exposed fully encapsulated for 3h daily to an exercise-heat stress (35°C and 30% relative humidity, walking on a motor-driven treadmill at a pace of 5 km h1 and a 4% inclination, in a work-rest cycle of 45min work and 15min rest). Two bipack CPCs (PC1 and PC2) were tested and the results were compared with those attained by two control suits - a standard cotton military BDU (CO1) and an impermeable material suit (CO2).Results:The physiological burden imposed by the two bilayer garments was within the boundaries set by the control conditions. Overall, PC2 induced a lower strain, which was closer to CO1, whereas PC1 was closer to CO2. Air permeability of the PC2 cloth was almost three times higher than that of PC1, enabling a better heat dissipation and consequently a lower physiological strain. Furthermore, air permeability characteristic of the fabrics, which is associated with its construction and weave, significantly correlated with the physiological strain, whereas the correlation with Rct, Ret, and weight was poor.Conclusions:The results emphasize the importance of air permeability in reducing the physiological strain induced by CPCs.
AB - Objectives:The high values of thermal resistance (Rct) and/or vapor resistance (Ret) of chemical protective clothing (CPC) induce a considerable thermal stress. The present study compared the physiological strain induced by CPCs and evaluates the relative importance of the fabrics' Rct, Ret, and air permeability in determining heat strain.Methods:Twelve young (20-30 years) healthy, heat-acclimated male subjects were exposed fully encapsulated for 3h daily to an exercise-heat stress (35°C and 30% relative humidity, walking on a motor-driven treadmill at a pace of 5 km h1 and a 4% inclination, in a work-rest cycle of 45min work and 15min rest). Two bipack CPCs (PC1 and PC2) were tested and the results were compared with those attained by two control suits - a standard cotton military BDU (CO1) and an impermeable material suit (CO2).Results:The physiological burden imposed by the two bilayer garments was within the boundaries set by the control conditions. Overall, PC2 induced a lower strain, which was closer to CO1, whereas PC1 was closer to CO2. Air permeability of the PC2 cloth was almost three times higher than that of PC1, enabling a better heat dissipation and consequently a lower physiological strain. Furthermore, air permeability characteristic of the fabrics, which is associated with its construction and weave, significantly correlated with the physiological strain, whereas the correlation with Rct, Ret, and weight was poor.Conclusions:The results emphasize the importance of air permeability in reducing the physiological strain induced by CPCs.
KW - heat strain
KW - heat stress
KW - protective garments
KW - thermal resistance
KW - water vapor resistance
UR - http://www.scopus.com/inward/record.url?scp=84883152739&partnerID=8YFLogxK
U2 - 10.1093/annhyg/met003
DO - 10.1093/annhyg/met003
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 23378525
AN - SCOPUS:84883152739
SN - 0003-4878
VL - 57
SP - 866
EP - 874
JO - Annals of Occupational Hygiene
JF - Annals of Occupational Hygiene
IS - 7
ER -