Reliability of the Dynavision™ D2 for assessing reaction time performance

  • Adam J. Wells
  • , Jay R. Hoffman
  • , Kyle S. Beyer
  • , Adam R. Jajtner
  • , Adam M. Gonzalez
  • , Jeremy R. Townsend
  • , Gerald T. Mangine
  • , Edward H. Robinson IV
  • , William P. McCormack
  • , Maren S. Fragala
  • , Jeffrey R. Stout

פרסום מחקרי: פרסום בכתב עתמאמרביקורת עמיתים

64 ציטוטים ‏(Scopus)

תקציר

Recently, the Dynavision™ D2 Visuomotor Training Device (D2) has emerged as a tool in the assessment of reaction time (RT); however, information regarding the reliability of the D2 have been limited, and to date, reliability data have been limited to non-generalizable samples. Therefore, the purpose of this study was to establish intraclass correlation coefficients (ICC2,1) for the D2 that are generalizable across a population of recreationally active young adults. Forty-two recreationally active men and women (age: 23.41 ± 4.84 years; height: 1.72 ± 0.11 m; mass: 76.62 ± 18.26 Kg) completed 6 trials for three RT tasks of increasing complexity. Each trial was separated by at least 48-hours. A repeated measures ANOVA was used to detect differences in performance across the six trials. Intraclass correlation coefficients (ICC2,1) standard error of measurement (SEM), and minimal differences (MD) were used to determine the reliability of the D2 from the two sessions with the least significant difference score. Moderate to strong reliability was demonstrated for visual RT (ICC2,1: 0.84, SEM: 0.033), and reactive ability in both Mode A and Mode B tasks (Mode A hits: ICC2,1: 0.75, SEM: 5.44; Mode B hits: ICC2,1: 0.73, SEM: 8.57). Motor RT (ICC2,1: 0.63, SEM: 0.035s) showed fair reliability, while average RT per hit for Modes A and B showed moderate reliability (ICC2,1: 0.68, SEM: 0.43 s and ICC2,1: 0.72, SEM: 0.03 s respectively). It appears that one familiarization trial is necessary for the choice reaction time (CRT) task while three familiarization trials are necessary for reactive RT tasks. In conclusion, results indicate that the Dynavision™ D2 is a reliable device to assess neuromuscular reactivity given that an adequate practice is provided. The data presented are generalizable to a population of recreationally active young adults.

שפה מקוריתאנגלית
עמודים (מ-עד)145-150
מספר עמודים6
כתב עתJournal of Sports Science and Medicine
כרך13
מספר גיליון1
סטטוס פרסוםפורסם - מרץ 2014
פורסם באופן חיצוניכן

טביעת אצבע

להלן מוצגים תחומי המחקר של הפרסום 'Reliability of the Dynavision™ D2 for assessing reaction time performance'. יחד הם יוצרים טביעת אצבע ייחודית.

פורמט ציטוט ביבליוגרפי