Proof of concept of a new real-time metasurface sensor for micropoison monitoring in aqueous solutions is proposed in this study. The sensor comprises a perfect absorber metasurface and gold nanoparticle layer on the front side of it. Frequency-domain terahertz spectroscopy system was used to measure the resonance frequency shift due to the presence of the micropoison. The perfect absorber metasurface sensor was fabricated using a double-sided FR4 substrate printed board circuit, which is very inexpensive. A significant increase in the metasurface sensor sensitivity was achieved by adding a gold nanoparticle layer to the gap of the double split rectangular resonator on the front side of the metasurface sensor.
| שפה מקורית | אנגלית |
|---|---|
| מספר המאמר | 1279 |
| כתב עת | Sensors |
| כרך | 22 |
| מספר גיליון | 3 |
| מזהי עצם דיגיטלי (DOIs) | |
| סטטוס פרסום | פורסם - 1 פבר׳ 2022 |