דילוג לניווט ראשי דילוג לחיפוש דילוג לתוכן הראשי

Fast cool-down J-T cryocooler to 88K

פרסום מחקרי: פרק בספר / בדוח / בכנספרסום בספר כנסביקורת עמיתים

3 ציטוטים ‏(Scopus)

תקציר

Fast cool-down is usually implemented with J-T cryocoolers which also enable low-cost and small-scale systems. In this paper, we describe an analysis for achieving cool-down time of a few seconds to 88K, using argon as the main coolant, and a few minutes of steady state cooling. It appears that in certain conditions a simple fixed orifice cryocooler may reach the performances of cryocoolers with a pre-cooling stage. Therefore, according to system demands, cost reduction, reliability, and manufacturing considerations the use of argon as a single coolant may be preferable over pre-cooling with another coolant, such as krypton. The investigation was made by a detailed numeric simulation and the results were successfully verified against experimental data.

שפה מקוריתאנגלית
כותר פרסום המארחAdvances in Cryogenic Engineering - Transactions of the Cryogenic Engineering Conference - CEC
עמודים1025-1032
מספר עמודים8
מזהי עצם דיגיטלי (DOIs)
סטטוס פרסוםפורסם - 2008
פורסם באופן חיצוניכן
אירועTransactions of the Cryogenic Engineering Conference, CEC 2007 - hattanooga, TN, ארצות הברית
משך הזמן: 16 יולי 200720 יולי 2007

סדרות פרסומים

שםAIP Conference Proceedings
כרך985
ISSN (מודפס)0094-243X
ISSN (אלקטרוני)1551-7616

כנס

כנסTransactions of the Cryogenic Engineering Conference, CEC 2007
מדינה/אזורארצות הברית
עירhattanooga, TN
תקופה16/07/0720/07/07

טביעת אצבע

להלן מוצגים תחומי המחקר של הפרסום 'Fast cool-down J-T cryocooler to 88K'. יחד הם יוצרים טביעת אצבע ייחודית.