תקציר
In this paper, average modeling and analysis of a dual-supercapacitor bank, actively balanced by a bidirectional buck-boost converter, is presented. In such a system, natural balancing is achieved when the converter is operated in open loop with 50% duty cycle, eliminating the need for measuring the voltage of each storage device. Nevertheless, excessive currents arise even for slight voltage misbalance because of the highly underdamped nature of the system. In order to remedy this drawback, bidirectional pulse-by-pulse inductor current limitation is introduced, which is equivalent to adding a peak-current-mode-like control loop to the system. Since the duty cycle never exceeds 50%, compensation ramp is not required to maintain stability. On the other hand, while the uncontrolled system dynamics is linear, introducing the current limit mechanism turns the closed-loop dynamics into a nonlinear one, burdening the analysis task and thus calling for suitable average model to perform fast simulations for system analysis. Therefore, dynamical equations of the system are developed in order to derive the switching-cycle-averaged model and reveal the tradeoff between current limit level, balancing time and efficiency for the worst case of imbalance. Simulations and experiments support the presented findings.
| שפה מקורית | אנגלית |
|---|---|
| מספר המאמר | 7442852 |
| עמודים (מ-עד) | 1570-1578 |
| מספר עמודים | 9 |
| כתב עת | IEEE Transactions on Power Electronics |
| כרך | 32 |
| מספר גיליון | 2 |
| מזהי עצם דיגיטלי (DOIs) | |
| סטטוס פרסום | פורסם - פבר׳ 2017 |
טביעת אצבע
להלן מוצגים תחומי המחקר של הפרסום 'Average Modeling and Performance Analysis of Voltage Sensorless Active Supercapacitor Balancer with Peak Current Protection'. יחד הם יוצרים טביעת אצבע ייחודית.פורמט ציטוט ביבליוגרפי
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver