TY - JOUR
T1 - A Multichannel Microfluidic Sensing Cartridge for Bioanalytical Applications of Monolithic Quartz Crystal Microbalance
AU - Calero, María
AU - Fernández, Román
AU - García, Pablo
AU - García, José Vicente
AU - García, María
AU - Gamero-Sandemetrio, Esther
AU - Reviakine, Ilya
AU - Arnau, Antonio
AU - Jiménez, Yolanda
N1 - Publisher Copyright:
© 2020 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2020/12
Y1 - 2020/12
N2 - Integrating acoustic wave sensors into lab-on-a-chip (LoC) devices is a well-known challenge. We address this challenge by designing a microfluidic device housing a monolithic array of 24 high-fundamental frequency quartz crystal microbalance with dissipation (HFF-QCMD) sensors. The device features six 6-µL channels of four sensors each for low-volume parallel measurements, a sealing mechanism that provides appropriate pressure control while assuring liquid confinement and maintaining good stability, and provides a mechanical, electrical, and thermal interface with the characterization electronics. We validate the device by measuring the response of the HFF-QCMD sensors to the air-to-liquid transition, for which the robust Kanazawa–Gordon–Mason theory exists, and then by studying the adsorption of model bioanalytes (neutravidin and biotinylated albumin). With these experiments, we show how the effects of the protein–surface interactions propagate within adsorbed protein multilayers, offering essentially new insight into the design of affinity-based bioanalytical sensors.
AB - Integrating acoustic wave sensors into lab-on-a-chip (LoC) devices is a well-known challenge. We address this challenge by designing a microfluidic device housing a monolithic array of 24 high-fundamental frequency quartz crystal microbalance with dissipation (HFF-QCMD) sensors. The device features six 6-µL channels of four sensors each for low-volume parallel measurements, a sealing mechanism that provides appropriate pressure control while assuring liquid confinement and maintaining good stability, and provides a mechanical, electrical, and thermal interface with the characterization electronics. We validate the device by measuring the response of the HFF-QCMD sensors to the air-to-liquid transition, for which the robust Kanazawa–Gordon–Mason theory exists, and then by studying the adsorption of model bioanalytes (neutravidin and biotinylated albumin). With these experiments, we show how the effects of the protein–surface interactions propagate within adsorbed protein multilayers, offering essentially new insight into the design of affinity-based bioanalytical sensors.
KW - biosensor
KW - flow cell
KW - food safety
KW - HFF-QCM (high fundamental frequency quartz crystal microbalance)
KW - mass transport
KW - MQCM (monolithic quartz crystal microbalance)
KW - PoC (point of care)
UR - https://www.scopus.com/pages/publications/85097036828
U2 - 10.3390/BIOS10120189
DO - 10.3390/BIOS10120189
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 33255411
AN - SCOPUS:85097036828
SN - 2079-6374
VL - 10
JO - Biosensors
JF - Biosensors
IS - 12
M1 - 189
ER -