Unreliability of disc diffusion test for screening for reduced penicillin susceptibility in Neisseria meningitidis

Colin Block, Yehudit Davidson, Nathan Keller

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

The 2-U penicillin and 1-μg oxacillin discs proposed for screening meningococci for susceptibility to penicillin were evaluated by using MICs measured by the E test. The discs yielded unacceptably high frequencies of misclassification of susceptibility category and should be abandoned in favor of MIC estimations. An agreed breakpoint for reduced penicillin susceptibility in meningococci is needed for the E test.

Original languageEnglish
Pages (from-to)3103-3104
Number of pages2
JournalJournal of Clinical Microbiology
Volume36
Issue number10
DOIs
StatePublished - Oct 1998
Externally publishedYes

Fingerprint

Dive into the research topics of 'Unreliability of disc diffusion test for screening for reduced penicillin susceptibility in Neisseria meningitidis'. Together they form a unique fingerprint.

Cite this