T1 - The Trade-Off between Airborne Pandemic Control and Energy Consumption Using Air Ventilation Solutions
AU - Alexi, Ariel
AU - Rosenfeld, Ariel
AU - Lazebnik, Teddy
N1 - Publisher Copyright:
© 2022 by the authors.
PY - 2022/11
Y1 - 2022/11
N2 - Airborne diseases cause high mortality and adverse socioeconomic consequences. Due to urbanization, more people spend more time indoors. According to recent research, air ventilation reduces long-range airborne transmission in indoor settings. However, air ventilation solutions often incur significant energy costs and ecological footprints. The trade-offs between energy consumption and pandemic control indoors have not yet been thoroughly analyzed. In this work, we use advanced sensors to monitor the energy consumption and pandemic control capabilities of an air-conditioning system, a pedestal fan, and an open window in hospital rooms, classrooms, and conference rooms. A simulation of an indoor airborne pandemic spread of Coronavirus (COVID-19) is used to analyze the Pareto front. For the three examined room types, the Pareto front consists of all three air ventilation solutions, with some ventilation configurations demonstrating significant inefficiencies. Specifically, air-conditioning is found to be efficient only at a very high energy cost and fans seem to pose a reasonable alternative. To conclude, a more informed ventilation policy can bring about a more desirable compromise between energy consumption and pandemic spread control.
AB - Airborne diseases cause high mortality and adverse socioeconomic consequences. Due to urbanization, more people spend more time indoors. According to recent research, air ventilation reduces long-range airborne transmission in indoor settings. However, air ventilation solutions often incur significant energy costs and ecological footprints. The trade-offs between energy consumption and pandemic control indoors have not yet been thoroughly analyzed. In this work, we use advanced sensors to monitor the energy consumption and pandemic control capabilities of an air-conditioning system, a pedestal fan, and an open window in hospital rooms, classrooms, and conference rooms. A simulation of an indoor airborne pandemic spread of Coronavirus (COVID-19) is used to analyze the Pareto front. For the three examined room types, the Pareto front consists of all three air ventilation solutions, with some ventilation configurations demonstrating significant inefficiencies. Specifically, air-conditioning is found to be efficient only at a very high energy cost and fans seem to pose a reasonable alternative. To conclude, a more informed ventilation policy can bring about a more desirable compromise between energy consumption and pandemic spread control.
KW - air ventilation
KW - airborne transmission and control
KW - energy consumption
KW - indoors pandemic spread
UR - http://www.scopus.com/inward/record.url?scp=85142728348&partnerID=8YFLogxK
U2 - 10.3390/s22228594
DO - 10.3390/s22228594
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 36433189
AN - SCOPUS:85142728348
SN - 1424-8220
VL - 22
JO - Sensors
JF - Sensors
IS - 22
M1 - 8594