T1 - SPECT attenuation artifacts in normal and overweight persons
T2 - Insights from a retrospective comparison of Rb-82 positron emission tomography and TI-201 SPECT myocardial perfusion imaging
AU - Freedman, Nanette
AU - Schechter, David
AU - Klein, Martine
AU - Marciano, Rami
AU - Rozenman, Yoseph
AU - Chisin, Roland
PY - 2000
Y1 - 2000
N2 - Purpose: Myocardial perfusion imaging can be performed using SPECT or positron emission tomography (PET). SPECT has lower specificity than PET, largely as a result of attenuation artifacts; however, it is more widely available. The authors describe a study of the effect of sex and body weight on the incidence of SPECT attenuation artifacts using a retrospective comparison of TI-201 SPECT and Rb PET. Methods: One hundred sixty-one persons (101 men, 60 women; 81 normal weight, 80 overweight) underwent TI-201 SPECT and Rb PET. The incidence of observed perfusion defects was studied in territories of the three major coronary arteries. SPECT and PET results were also compared with those of angiography in a subset of 75 patients. Results: One hundred fourteen defects were reported on Rb PET compared with 176 defects with TI-201 SPECT. Excess TI-201 SPECT defects occurred in male and female, normal-weight and overweight persons. The average specificity was 64% for TI-201 SPECT and 84% for Rb PET, reflecting this difference. Conclusions: Attenuation artifacts in TI-201 SPECT occur frequently and are not confined to easily identifiable subgroups of patients. Therefore, measures to improve specificity of SPECT (e.g., prone or gated imaging) or alternative imaging techniques such as PET have potential advantages for everyone, not simply for obese patients and women with large breasts. In addition, awareness of the prevalence of SPECT attenuation artifacts, in both sexes and all weight categories, may contribute to improved accuracy of interpretation.
AB - Purpose: Myocardial perfusion imaging can be performed using SPECT or positron emission tomography (PET). SPECT has lower specificity than PET, largely as a result of attenuation artifacts; however, it is more widely available. The authors describe a study of the effect of sex and body weight on the incidence of SPECT attenuation artifacts using a retrospective comparison of TI-201 SPECT and Rb PET. Methods: One hundred sixty-one persons (101 men, 60 women; 81 normal weight, 80 overweight) underwent TI-201 SPECT and Rb PET. The incidence of observed perfusion defects was studied in territories of the three major coronary arteries. SPECT and PET results were also compared with those of angiography in a subset of 75 patients. Results: One hundred fourteen defects were reported on Rb PET compared with 176 defects with TI-201 SPECT. Excess TI-201 SPECT defects occurred in male and female, normal-weight and overweight persons. The average specificity was 64% for TI-201 SPECT and 84% for Rb PET, reflecting this difference. Conclusions: Attenuation artifacts in TI-201 SPECT occur frequently and are not confined to easily identifiable subgroups of patients. Therefore, measures to improve specificity of SPECT (e.g., prone or gated imaging) or alternative imaging techniques such as PET have potential advantages for everyone, not simply for obese patients and women with large breasts. In addition, awareness of the prevalence of SPECT attenuation artifacts, in both sexes and all weight categories, may contribute to improved accuracy of interpretation.
KW - Myocardial Imaging
KW - Obesity
KW - Positron Emission Tomography
KW - SPECT
UR - http://www.scopus.com/inward/record.url?scp=0033661702&partnerID=8YFLogxK
U2 - 10.1097/00003072-200012000-00014
DO - 10.1097/00003072-200012000-00014
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 11129138
AN - SCOPUS:0033661702
SN - 0363-9762
VL - 25
SP - 1019
EP - 1023
JO - Clinical Nuclear Medicine
JF - Clinical Nuclear Medicine
IS - 12
ER -