Abstract
Operational data for the separation of oxygen isotopes are given on flow rates, concentrations and concentration profiles of the isotope separation plant of the Weizmann Institute of Science which has reached steady‐state operational conditions with regard to the rare and more difficult to separate oxygen‐17 isotope. This plant consists of two sections, namely packed distillation columns and thermal diffusion columns. Data on the columns and packing characteristics are given. The concentrations reached in the distillation section are up to 98% of oxygen‐18 and up to 20% of oxygen‐17. In the thermal diffusion section, concentrations of oxygen‐18 up to 99.9% and of oxygen‐17 up to 96% have been attained.
| Original language | English |
|---|---|
| Pages (from-to) | 621-627 |
| Number of pages | 7 |
| Journal | Canadian Journal of Chemical Engineering |
| Volume | 50 |
| Issue number | 5 |
| DOIs | |
| State | Published - Oct 1972 |
| Externally published | Yes |
Fingerprint
Dive into the research topics of 'Process design considerations and steady‐state operational data for the separations of isotopes of oxygen'. Together they form a unique fingerprint.Cite this