TY - GEN
T1 - Post-angioplastic contact mechanics with different levels of artherosclerotic plaque
AU - Teodorescu, M.
AU - Rahnejat, H.
AU - Brand, Moshe
AU - Rosen, Jacob
PY - 2010
Y1 - 2010
N2 - The main goal of balloon angioplasty is to extend the active cross-section of a partly blocked artery. In the last stage of the medical operation, a metallic frame (stent) is introduced in the open space of the artery (lumen) and expanded to the desired diameter. It is generally accepted that some of the main causes of post-angioplasty restenosis are the global stresses induced in the artery by the expanding stent and the local interaction between the stent and the arterial wall. In a blocked artery a thick layer of hard plaque deposition usually covers a significant section of the wall. Therefore, to choose an appropriate stent and improve upon the angioplasty success rate, a fundamental understanding of the local interaction between the stent and the plaque, as well as between the stent and the healthy wall is vital. The goal of the present study is to find a correlation between the local thickness of the plaque layer, contact geometry and the stent/artery radial mismatch.
AB - The main goal of balloon angioplasty is to extend the active cross-section of a partly blocked artery. In the last stage of the medical operation, a metallic frame (stent) is introduced in the open space of the artery (lumen) and expanded to the desired diameter. It is generally accepted that some of the main causes of post-angioplasty restenosis are the global stresses induced in the artery by the expanding stent and the local interaction between the stent and the arterial wall. In a blocked artery a thick layer of hard plaque deposition usually covers a significant section of the wall. Therefore, to choose an appropriate stent and improve upon the angioplasty success rate, a fundamental understanding of the local interaction between the stent and the plaque, as well as between the stent and the healthy wall is vital. The goal of the present study is to find a correlation between the local thickness of the plaque layer, contact geometry and the stent/artery radial mismatch.
UR - http://www.scopus.com/inward/record.url?scp=80054764093&partnerID=8YFLogxK
U2 - 10.1115/IJTC2010-41145
DO - 10.1115/IJTC2010-41145
M3 - ???researchoutput.researchoutputtypes.contributiontobookanthology.conference???
AN - SCOPUS:80054764093
SN - 9780791844199
T3 - American Society of Mechanical Engineers, Tribology Division, TRIB
SP - 41
EP - 43
BT - STLE/ASME 2010 International Joint Tribology Conference, IJTC2010
T2 - STLE/ASME 2010 International Joint Tribology Conference, IJTC2010
Y2 - 17 October 2010 through 20 October 2010
ER -