TY - GEN
T1 - On the power of false negative awareness in indicator-based caching systems
AU - Cohen, Itamar
AU - Einziger, Gil
AU - Scalosub, Gabriel
N1 - Publisher Copyright:
© 2021 IEEE.
PY - 2021/7
Y1 - 2021/7
N2 - Distributed caching systems such as content distribution networks often advertise their content via lightweight approximate indicators (e.g., Bloom filters) to efficiently inform clients where each datum is likely cached. While false-positive indications are necessary and well understood, most existing works assume no false-negative indications. Our work illustrates practical scenarios where false-negatives are unavoidable and ignoring them has a significant impact on system performance. Specifically, we focus on false-negatives induced by indicator staleness, which arises whenever the system advertises the indicator only periodically, rather than immediately reporting every change in the cache. Such scenarios naturally occur, e.g., in bandwidth-constraint environments or when latency impedes each client's ability to obtain an updated indicator. Our work introduces novel false-negative aware access policies that continuously estimate the false-negative ratio and sometimes access caches despite negative indications. We present optimal policies for homogeneous settings and provide approximation guarantees for our algorithms in heterogeneous environments. We further perform an extensive simulation study with multiple real system traces. We show that our false-negative aware algorithms incur a significantly lower access cost than existing approaches or match the cost of these approaches while requiring an order of magnitude fewer resources (e.g., caching capacity or bandwidth).
AB - Distributed caching systems such as content distribution networks often advertise their content via lightweight approximate indicators (e.g., Bloom filters) to efficiently inform clients where each datum is likely cached. While false-positive indications are necessary and well understood, most existing works assume no false-negative indications. Our work illustrates practical scenarios where false-negatives are unavoidable and ignoring them has a significant impact on system performance. Specifically, we focus on false-negatives induced by indicator staleness, which arises whenever the system advertises the indicator only periodically, rather than immediately reporting every change in the cache. Such scenarios naturally occur, e.g., in bandwidth-constraint environments or when latency impedes each client's ability to obtain an updated indicator. Our work introduces novel false-negative aware access policies that continuously estimate the false-negative ratio and sometimes access caches despite negative indications. We present optimal policies for homogeneous settings and provide approximation guarantees for our algorithms in heterogeneous environments. We further perform an extensive simulation study with multiple real system traces. We show that our false-negative aware algorithms incur a significantly lower access cost than existing approaches or match the cost of these approaches while requiring an order of magnitude fewer resources (e.g., caching capacity or bandwidth).
KW - Access strategies
KW - Cache sharing
KW - Cooperative caching
KW - Information centric networks
KW - Network caching
KW - Replica selection
KW - Uncertainty
UR - http://www.scopus.com/inward/record.url?scp=85117109994&partnerID=8YFLogxK
U2 - 10.1109/ICDCS51616.2021.00014
DO - 10.1109/ICDCS51616.2021.00014
M3 - ???researchoutput.researchoutputtypes.contributiontobookanthology.conference???
AN - SCOPUS:85117109994
T3 - Proceedings - International Conference on Distributed Computing Systems
SP - 46
EP - 56
BT - Proceedings - 2021 IEEE 41st International Conference on Distributed Computing Systems, ICDCS 2021
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 41st IEEE International Conference on Distributed Computing Systems, ICDCS 2021
Y2 - 7 July 2021 through 10 July 2021
ER -