TY - JOUR
T1 - Multipole analysis of heart rate variability as a predictor of imminent ventricular arrhythmias in ICD patients
AU - Rozen, Guy
AU - Kobo, Roi
AU - Beinart, Roy
AU - Feldman, Shlomo
AU - Sapunar, Michal
AU - Luria, David
AU - Eldar, Michael
AU - Levitan, Jacob
AU - Glikson, Michael
PY - 2013/11
Y1 - 2013/11
N2 - Background Contemporary implantable cardiac defibrillators (ICD) enable storage of multiple, preepisode R-R recordings in patients who suffered from ventricular tachyarrhythmia (VTA). Timely prediction of VTA, using heart rate variability (HRV) analysis techniques, may facilitate the implementation of preventive and therapeutic strategies. Aim To evaluate the novel multipole method of the HRV analysis in prediction of imminent VTAs in ICD patients. Methods We screened patients from the Biotronik HAWAI Registry (Heart Rate Analysis with Automated ICDs). A total of 28 patients from the HAWAI registries (phase I and II), having medical records, who had experienced documented, verified VTA during the 2-year follow-up, were included in our analysis. HRV during preepisode recordings of 4,500 R-R intervals were analyzed using the Dyx parameter and compared to HRV of similar length recordings from the same patients that were not followed by arrhythmia. Results Our study population consisted mainly of men 25 of 28 (89%), average age of 64.8 ± 9.4 years, 92% with coronary artery disease. HRV during 64 preevent recordings (2.3 events per patient on average) was analyzed and compared with 60 control recordings. The multipole method of HRV analysis showed 50% sensitivity and 91.6% specificity for prediction of ventricular tachycardia/ventricular fibrillation in the study population, with 84.5% positive predictive value. No statistically significant correlation was found between various clinical parameters and the sensitivity of imminent VTA predetection in our patients. Conclusion The multipole method of HRV analysis emerges as a highly specific, possible predictor of imminent VTA, providing an early warning allowing to prepare for an arrhythmic episode.
AB - Background Contemporary implantable cardiac defibrillators (ICD) enable storage of multiple, preepisode R-R recordings in patients who suffered from ventricular tachyarrhythmia (VTA). Timely prediction of VTA, using heart rate variability (HRV) analysis techniques, may facilitate the implementation of preventive and therapeutic strategies. Aim To evaluate the novel multipole method of the HRV analysis in prediction of imminent VTAs in ICD patients. Methods We screened patients from the Biotronik HAWAI Registry (Heart Rate Analysis with Automated ICDs). A total of 28 patients from the HAWAI registries (phase I and II), having medical records, who had experienced documented, verified VTA during the 2-year follow-up, were included in our analysis. HRV during preepisode recordings of 4,500 R-R intervals were analyzed using the Dyx parameter and compared to HRV of similar length recordings from the same patients that were not followed by arrhythmia. Results Our study population consisted mainly of men 25 of 28 (89%), average age of 64.8 ± 9.4 years, 92% with coronary artery disease. HRV during 64 preevent recordings (2.3 events per patient on average) was analyzed and compared with 60 control recordings. The multipole method of HRV analysis showed 50% sensitivity and 91.6% specificity for prediction of ventricular tachycardia/ventricular fibrillation in the study population, with 84.5% positive predictive value. No statistically significant correlation was found between various clinical parameters and the sensitivity of imminent VTA predetection in our patients. Conclusion The multipole method of HRV analysis emerges as a highly specific, possible predictor of imminent VTA, providing an early warning allowing to prepare for an arrhythmic episode.
KW - ICD
KW - heart rate variability
KW - ventricular arrhythmia
UR - http://www.scopus.com/inward/record.url?scp=84886784456&partnerID=8YFLogxK
U2 - 10.1111/pace.12180
DO - 10.1111/pace.12180
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 23713754
AN - SCOPUS:84886784456
SN - 0147-8389
VL - 36
SP - 1342
EP - 1347
JO - PACE - Pacing and Clinical Electrophysiology
JF - PACE - Pacing and Clinical Electrophysiology
IS - 11
ER -