Mass transfer and drop size in liquid-liquid cu extraction with lix 84n if motionless mixers

D. Wolf, A. Sembira, J. C. Merchuk

Research output: Chapter in Book/Report/Conference proceedingChapterpeer-review

Abstract

Data of drop size and mass transfer in the extraction of Cu from an aqueous solution into a solution of LIX 84N in kerosene for several lengths of motionless mixers of the Sulzer type SMV-4 and 3/4″ diameter is presented. Previous data obtained with same static mixers and other types of mixers will also be presented for background and comparison purposes.

Original languageEnglish
Title of host publicationProcess Metallurgy
Pages1307-1312
Number of pages6
DOIs
StatePublished - 1 Jan 1992

Publication series

NameProcess Metallurgy
Volume7
ISSN (Print)1572-4409

Fingerprint

Dive into the research topics of 'Mass transfer and drop size in liquid-liquid cu extraction with lix 84n if motionless mixers'. Together they form a unique fingerprint.

Cite this