TY - JOUR
T1 - Investigation of risks for cerebral embolism associated with the hemodynamics of cardiopulmonary bypass cannula
T2 - A numerical model
AU - Avrahami, Idit
AU - Dilmoney, Benny
AU - Azuri, Aliza
AU - Brand, Moshe
AU - Cohen, Oved
AU - Shani, Liran
AU - Nir, Rony Reuven
AU - Bolotin, Gil
PY - 2013/10
Y1 - 2013/10
N2 - Cerebral emboli originating in the ascending aorta are a major cause of noncardiac complications following cardiac surgery. The hemodynamics of the aortic cannula has been proven to play a significant role in emboli generation and distribution. The aim of the current study was to perform a thorough numerical investigation in order to examine the effect of the design and orientation of the cannula used during cardiopulmonary bypass on the risk to develop cerebral embolism. Hemodynamic analyses compared numerical models of 27 cases consisting of six different cannula orientations, four aortic anatomies, and three cannula designs. The cannula designs included a straight-tip (ST) cannula, a moderately curved tip cannula (TIP1), and a sharp-angle curved cannula (TIP2). Outcome measures included hemodynamic parameters such as emanating jet velocity, jet velocity drop, maximal shear stress, aortic wall reaction, emboli pathlines and distribution between upper and lower vessels, and stagnation regions. Based on these parameters, the risks for hemolysis, atheroembolism, and cerebral embolism were evaluated and compared. On one hand, the jet emerging from the ST cannula generated large wall-shear stress at the aortic wall; this may have triggered the erosion and distribution of embolic atheromatous debris from the aortic arch. On the other hand, it diverted more emboli from the clamp region to the descending aorta and thus reduced the risk for cerebral embolism. The TIP1 cannula demonstrated less shear stress on the aortic wall and diverted more emboli from the clamp region toward the upper vessels. The TIP2 cannula exhibited a stronger emanating jet, higher shear stress inside the cannula, and highly disturbed flow, which was more stagnant near the clamp region. Current findings support the significant impact of the cannula design and orientation on emboli generation and distribution. Specifically, the straight tip cannula demonstrated a reduced risk of cerebral embolism, which may be pivotal in the clinical setting.
AB - Cerebral emboli originating in the ascending aorta are a major cause of noncardiac complications following cardiac surgery. The hemodynamics of the aortic cannula has been proven to play a significant role in emboli generation and distribution. The aim of the current study was to perform a thorough numerical investigation in order to examine the effect of the design and orientation of the cannula used during cardiopulmonary bypass on the risk to develop cerebral embolism. Hemodynamic analyses compared numerical models of 27 cases consisting of six different cannula orientations, four aortic anatomies, and three cannula designs. The cannula designs included a straight-tip (ST) cannula, a moderately curved tip cannula (TIP1), and a sharp-angle curved cannula (TIP2). Outcome measures included hemodynamic parameters such as emanating jet velocity, jet velocity drop, maximal shear stress, aortic wall reaction, emboli pathlines and distribution between upper and lower vessels, and stagnation regions. Based on these parameters, the risks for hemolysis, atheroembolism, and cerebral embolism were evaluated and compared. On one hand, the jet emerging from the ST cannula generated large wall-shear stress at the aortic wall; this may have triggered the erosion and distribution of embolic atheromatous debris from the aortic arch. On the other hand, it diverted more emboli from the clamp region to the descending aorta and thus reduced the risk for cerebral embolism. The TIP1 cannula demonstrated less shear stress on the aortic wall and diverted more emboli from the clamp region toward the upper vessels. The TIP2 cannula exhibited a stronger emanating jet, higher shear stress inside the cannula, and highly disturbed flow, which was more stagnant near the clamp region. Current findings support the significant impact of the cannula design and orientation on emboli generation and distribution. Specifically, the straight tip cannula demonstrated a reduced risk of cerebral embolism, which may be pivotal in the clinical setting.
KW - Aortic cannula
KW - Cardiopulmonary bypass
KW - Cerebral emboli
KW - Computational fluid dynamics
UR - http://www.scopus.com/inward/record.url?scp=84886892443&partnerID=8YFLogxK
U2 - 10.1111/aor.12094
DO - 10.1111/aor.12094
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 24138494
AN - SCOPUS:84886892443
SN - 0160-564X
VL - 37
SP - 857
EP - 865
JO - Artificial Organs
JF - Artificial Organs
IS - 10
ER -