High-dose intravenous isosorbide-dinitrate is safer and better than Bi-PAP ventilation combined with conventional treatment for severe pulmonary edema

Ahuva Sharon, Isaac Shpirer, Edo Kaluski, Yaron Moshkovitz, Olga Milovanov, Roman Polak, Alex Blatt, Avi Simovitz, Ori Shaham, Zvi Faigenberg, Michael Metzger, David Stav, Robert Yogev, Ahuva Golik, Rikardo Krakover, Zvi Vered, Gad Cotter

Research output: Contribution to journalArticlepeer-review

190 Scopus citations

Abstract

OBJECTIVE: To determine the feasibility, safety and efficacy of bilevel positive airway ventilation (BiPAP) in the treatment of severe pulmonary edema compared to high dose nitrate therapy. BACKGROUND: Although noninvasive ventilation is increasingly used in the treatment of pulmonary edema, its efficacy has not been compared prospectively with newer treatment modalities. METHODS: We enrolled 40 consecutive patients with severe pulmonary edema (oxygen saturation <90% on room air prior to treatment). All patients received oxygen at a rate of 10 liter/min, intravenous (IV) furosemide 80 mg and IV morphine 3 mg. Thereafter patients were randomly allocated to receive 1) repeated boluses of IV isosorbide-dinitrate (ISDN) 4 mg every 4 min (n = 20), and 2) BiPAP ventilation and standard dose nitrate therapy (n = 20). Treatment was administered until oxygen saturation increased above 96% or systolic blood pressure decreased to below 110 mm Hg or by more than 30%. Patients whose conditions deteriorated despite therapy were intubated and mechanically ventilated. All treatment was delivered by mobile intensive care units prior to hospital arrival. RESULTS: Patients treated by BiPAP had significantly more adverse events. Two BiPAP treated patients died versus zero in the high dose ISDN group. Sixteen BiPAP treated patients (80%) required intubation and mechanical ventilation compared to four (20%) in the high dose ISDN group (p = 0.0004). Myocardial infarction (MI) occurred in 11 (55%) and 2 (10%) patients, respectively (p = 0.006). The combined primary end point (death, mechanical ventilation or MI) was observed in 17 (85%) versus 5 (25%) patients, respectively (p = 0.0003). After 1 h of treatment, oxygen saturation increased to 96 ± 4% in the high dose ISDN group as compared to 89 ± 7% in the BiPAP group (p = 0.017). Due to the significant deterioration observed in patients enrolled in the BiPAP arm, the study was prematurely terminated by the safety committee. CONCLUSIONS: High dose ISDN is safer and better than BiPAP ventilation combined with conventional therapy in patients with severe pulmonary edema. (C) 2000 by the American College of Cardiology.

Original languageEnglish
Pages (from-to)832-837
Number of pages6
JournalJournal of the American College of Cardiology
Volume36
Issue number3
DOIs
StatePublished - 2000
Externally publishedYes

Fingerprint

Dive into the research topics of 'High-dose intravenous isosorbide-dinitrate is safer and better than Bi-PAP ventilation combined with conventional treatment for severe pulmonary edema'. Together they form a unique fingerprint.

Cite this