T1 - Determination of creatinine level in patient blood samples by Fourier NIR spectroscopy and multivariate analysis in comparison with biochemical assay
AU - Barnea, Zvi Hai
AU - Abookasis, David
N1 - Publisher Copyright:
© 2019 The Author(s).
PY - 2019/11/1
Y1 - 2019/11/1
N2 - In this paper, in vivo spectra from 23 patients' blood samples with various Creatinine (Cr) concentration levels ranging from 0.96 to 12.5 mg/dL were measured using Fourier transform near-infrared spectrometer (FT-NIRS) and spectrum quantitative analysis method. Since Cr undergoes passive filtration, it serves as a key biomarker of kidneys function via the estimation of glomerular filtration rate. Thus, increased blood Cr concentration reflects impaired renal function. After spectra pre-processing and outlier exclusion, a spectral model was developed based on partial least squares regression (PLSR) method, wherein Cr concentrations correlated with filtered NIR spectra across several peaks, where Cr is known to absorb NIR light. Several statistical metrics were applied to estimate the model efficiency during data analysis. Comparison of spectra-derived concentrations to reference Cr measurements by the current gold-standard Jaffe's method held in hospital lab revealed a Cr prediction accuracy of 1.64mg/dL with good correlation of R=0.9. Bland-Altman plots were used to compare between our calculations and reference lab values and reveal minimal bias between the two. The finding presented the potential of FT-NIRS coupled with PLSR technique for Cr determination.
AB - In this paper, in vivo spectra from 23 patients' blood samples with various Creatinine (Cr) concentration levels ranging from 0.96 to 12.5 mg/dL were measured using Fourier transform near-infrared spectrometer (FT-NIRS) and spectrum quantitative analysis method. Since Cr undergoes passive filtration, it serves as a key biomarker of kidneys function via the estimation of glomerular filtration rate. Thus, increased blood Cr concentration reflects impaired renal function. After spectra pre-processing and outlier exclusion, a spectral model was developed based on partial least squares regression (PLSR) method, wherein Cr concentrations correlated with filtered NIR spectra across several peaks, where Cr is known to absorb NIR light. Several statistical metrics were applied to estimate the model efficiency during data analysis. Comparison of spectra-derived concentrations to reference Cr measurements by the current gold-standard Jaffe's method held in hospital lab revealed a Cr prediction accuracy of 1.64mg/dL with good correlation of R=0.9. Bland-Altman plots were used to compare between our calculations and reference lab values and reveal minimal bias between the two. The finding presented the potential of FT-NIRS coupled with PLSR technique for Cr determination.
KW - Creatinine
KW - Fourier transform near-infrared spectroscopy
KW - blood samples
KW - chemometrics
KW - statistical analysis
UR - http://www.scopus.com/inward/record.url?scp=85068460447&partnerID=8YFLogxK
U2 - 10.1142/S1793545819500159
DO - 10.1142/S1793545819500159
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:85068460447
SN - 1793-5458
VL - 12
JO - Journal of Innovative Optical Health Sciences
JF - Journal of Innovative Optical Health Sciences
IS - 6
M1 - 1950015
ER -