TY - JOUR
T1 - Average Modeling and Performance Analysis of Voltage Sensorless Active Supercapacitor Balancer with Peak Current Protection
AU - Yuhimenko, V.
AU - Geula, G.
AU - Agranovich, G.
AU - Averbukh, M.
AU - Kuperman, A.
N1 - Publisher Copyright:
© 1986-2012 IEEE.
PY - 2017/2
Y1 - 2017/2
N2 - In this paper, average modeling and analysis of a dual-supercapacitor bank, actively balanced by a bidirectional buck-boost converter, is presented. In such a system, natural balancing is achieved when the converter is operated in open loop with 50% duty cycle, eliminating the need for measuring the voltage of each storage device. Nevertheless, excessive currents arise even for slight voltage misbalance because of the highly underdamped nature of the system. In order to remedy this drawback, bidirectional pulse-by-pulse inductor current limitation is introduced, which is equivalent to adding a peak-current-mode-like control loop to the system. Since the duty cycle never exceeds 50%, compensation ramp is not required to maintain stability. On the other hand, while the uncontrolled system dynamics is linear, introducing the current limit mechanism turns the closed-loop dynamics into a nonlinear one, burdening the analysis task and thus calling for suitable average model to perform fast simulations for system analysis. Therefore, dynamical equations of the system are developed in order to derive the switching-cycle-averaged model and reveal the tradeoff between current limit level, balancing time and efficiency for the worst case of imbalance. Simulations and experiments support the presented findings.
AB - In this paper, average modeling and analysis of a dual-supercapacitor bank, actively balanced by a bidirectional buck-boost converter, is presented. In such a system, natural balancing is achieved when the converter is operated in open loop with 50% duty cycle, eliminating the need for measuring the voltage of each storage device. Nevertheless, excessive currents arise even for slight voltage misbalance because of the highly underdamped nature of the system. In order to remedy this drawback, bidirectional pulse-by-pulse inductor current limitation is introduced, which is equivalent to adding a peak-current-mode-like control loop to the system. Since the duty cycle never exceeds 50%, compensation ramp is not required to maintain stability. On the other hand, while the uncontrolled system dynamics is linear, introducing the current limit mechanism turns the closed-loop dynamics into a nonlinear one, burdening the analysis task and thus calling for suitable average model to perform fast simulations for system analysis. Therefore, dynamical equations of the system are developed in order to derive the switching-cycle-averaged model and reveal the tradeoff between current limit level, balancing time and efficiency for the worst case of imbalance. Simulations and experiments support the presented findings.
KW - Active balancing
KW - buck-boost converter
KW - current limitation
KW - dynamic model
KW - supercapacitor (SC) bank
UR - http://www.scopus.com/inward/record.url?scp=84999293168&partnerID=8YFLogxK
U2 - 10.1109/TPEL.2016.2547906
DO - 10.1109/TPEL.2016.2547906
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:84999293168
SN - 0885-8993
VL - 32
SP - 1570
EP - 1578
JO - IEEE Transactions on Power Electronics
JF - IEEE Transactions on Power Electronics
IS - 2
M1 - 7442852
ER -