TY - JOUR
T1 - Vision Transformer for Pretreatment Prediction of Pathologic Complete Response in Multi-center Breast DCE-MRI
AU - Fridman, Naomi
AU - Solway, Bubby
AU - Fridman, Tomer
AU - Barnea, Itamar
AU - Goldstein, Anat
N1 - Publisher Copyright:
© 2026 The Association of University Radiologists.
PY - 2026
Y1 - 2026
N2 - Rationale and Objectives Pretreatment prediction of pathologic complete response (pCR) is clinically important for guiding neoadjuvant chemotherapy (NAC), but robust multi-center benchmarks with standardized evaluation protocols remain limited. We evaluated a Vision Transformer (ViT) approach for pCR prediction from breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Materials and Methods We used BreastDCEDL, a public multi-center dataset comprising 2070 patients from the I-SPY1, I-SPY2, and Duke cohorts with predefined splits. Pre-contrast, early post-contrast, and late post-contrast phases were mapped to RGB channels for transfer learning from ImageNet-pretrained backbones. The held-out test set (n=175) included 32 pCR+ in I-SPY2 (99), 8 in Duke (41), and 12 in I-SPY1 (35). For I-SPY2, ViT scores were combined with clinical variables (age, HR/HER2 status, tumor volume, genomic score, treatment arm) via a Random Forest classifier. Results The ViT achieved AUC 0.72 (95% CI 0.64–0.80), sensitivity 0.27 (95% CI 0.15–0.40), and specificity 0.96 (95% CI 0.92–0.99). Performance varied across cohorts (AUC: I-SPY2 0.78, 95% CI 0.68–0.86, I-SPY1 0.68, 95% CI 0.46–0.89, Duke 0.54, 95% CI 0.27–0.80). In I-SPY2, clinical variables increased AUC to 0.85 overall ( n =99), a difference that was not statistically significant (DeLong P=0.06). Conclusion Cross-cohort variation highlights challenges in developing generalizable pretreatment response models under real-world heterogeneity. The high specificity supports potential utility for identifying non-responders, enabling earlier transition to alternative strategies. Code, data, and predefined splits are publicly available, establishing a reproducible benchmark.
AB - Rationale and Objectives Pretreatment prediction of pathologic complete response (pCR) is clinically important for guiding neoadjuvant chemotherapy (NAC), but robust multi-center benchmarks with standardized evaluation protocols remain limited. We evaluated a Vision Transformer (ViT) approach for pCR prediction from breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Materials and Methods We used BreastDCEDL, a public multi-center dataset comprising 2070 patients from the I-SPY1, I-SPY2, and Duke cohorts with predefined splits. Pre-contrast, early post-contrast, and late post-contrast phases were mapped to RGB channels for transfer learning from ImageNet-pretrained backbones. The held-out test set (n=175) included 32 pCR+ in I-SPY2 (99), 8 in Duke (41), and 12 in I-SPY1 (35). For I-SPY2, ViT scores were combined with clinical variables (age, HR/HER2 status, tumor volume, genomic score, treatment arm) via a Random Forest classifier. Results The ViT achieved AUC 0.72 (95% CI 0.64–0.80), sensitivity 0.27 (95% CI 0.15–0.40), and specificity 0.96 (95% CI 0.92–0.99). Performance varied across cohorts (AUC: I-SPY2 0.78, 95% CI 0.68–0.86, I-SPY1 0.68, 95% CI 0.46–0.89, Duke 0.54, 95% CI 0.27–0.80). In I-SPY2, clinical variables increased AUC to 0.85 overall ( n =99), a difference that was not statistically significant (DeLong P=0.06). Conclusion Cross-cohort variation highlights challenges in developing generalizable pretreatment response models under real-world heterogeneity. The high specificity supports potential utility for identifying non-responders, enabling earlier transition to alternative strategies. Code, data, and predefined splits are publicly available, establishing a reproducible benchmark.
KW - Breast cancer
KW - Dynamic contrast-enhanced MRI
KW - Neoadjuvant chemotherapy
KW - Pathologic complete response
KW - Vision Transformer
UR - https://www.scopus.com/pages/publications/105052505418
U2 - 10.1016/j.acra.2026.09.024
DO - 10.1016/j.acra.2026.09.024
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:105052505418
SN - 1076-6332
JO - Academic Radiology
JF - Academic Radiology
ER -