ملخص
Protective gear is mandatory for medical personnel treating casualties in a contaminated environment. In the present study, we assessed the ability of emergency medical technicians to insert an intravenous line in this situation. Sixty emergency medical technicians were randomized to a control group, wearing fatigues, and a study group, wearing full protective gear. The ability to insert an intravenous line in healthy volunteers was assessed 1, 2, 4, and 8 hours after randomization. We found no effect of protective gear (p = 0.543) or time in protective gear (p = 0.8869) on success rate or on time needed for successful task completion (p = 0.4005 and p = 0.9021, respectively). The overall success rate was 58.6%, 65% in the unprotected state and 56% in the protected state, and the time was 303 ± 115 and 351 ± 113 seconds, respectively. These findings suggest that introduction of an intravenous line is possible but time consuming even after a prolonged stay in full protective gear. Alternative methods for antidotal treatment, such as the use of automatic autoinjectors for intramuscular administration, might be suggested.
| اللغة الأصلية | الإنجليزيّة |
|---|---|
| الصفحات (من إلى) | 737-739 |
| عدد الصفحات | 3 |
| دورية | Military Medicine |
| مستوى الصوت | 164 |
| رقم الإصدار | 10 |
| المعرِّفات الرقمية للأشياء | |
| حالة النشر | نُشِر - أكتوبر 1999 |
بصمة
أدرس بدقة موضوعات البحث “The effect of a chemical protective ensemble on intravenous line insertion by emergency medical technicians'. فهما يشكلان معًا بصمة فريدة.قم بذكر هذا
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver