Sizing the Split DC Link Capacitance in Three-Phase Three-Level Bidirectional AC-DC Converters Operating with Arbitrary Power Factor Under Zero-Sequence Injection Restriction

نتاج البحث: نشر في مجلةمقالةمراجعة النظراء

2 اقتباسات (Scopus)

ملخص

The paper presents a methodology for determining the minimum split DC link capacitance for a family of three-phase, three-level grid-connected bidirectional AC-DC converters operating under arbitrary power factor under restriction of DC-only zero-sequence injection. The approach is based on the recently revealed generalized behavior of split DC link voltages in the above-mentioned converters family while distinguishing between leading and lagging power factors in order to highlight different impacts on split DC link capacitor voltages pulsating components. The minimum capacitance value is derived from the boundary condition, ensuring the mains voltage remains below or equal to the capacitor voltage at all times. It is revealed that operation with the lowest expected leading power factor should be employed as the design operating point. The accuracy of the proposed methodology is validated by simulations and experiments carried out employing a 10 kVA grid-connected T-type converter prototype. The results demonstrate close agreement between theoretical predictions and experiments, confirming the practical applicability of the proposed method.

اللغة الأصليةالإنجليزيّة
رقم المقال3159
دوريةApplied Sciences (Switzerland)
مستوى الصوت15
رقم الإصدار6
المعرِّفات الرقمية للأشياء
حالة النشرنُشِر - مارس 2025

بصمة

أدرس بدقة موضوعات البحث “Sizing the Split DC Link Capacitance in Three-Phase Three-Level Bidirectional AC-DC Converters Operating with Arbitrary Power Factor Under Zero-Sequence Injection Restriction'. فهما يشكلان معًا بصمة فريدة.

قم بذكر هذا