Measurements and simulations of the optical parameters of the Glow Discharge Detector (GDD) Focal Plane Array (FPA) millimeter wavelength imaging system

Moshe Shilemay, Daniel Rozban, Assaf Levanon, Yitzhak Yitzhaky, Natan S. Kopeika, Amir Abramovich

نتاج البحث: فصل من :كتاب / تقرير / مؤتمرمنشور من مؤتمرمراجعة النظراء

ملخص

The optical parameters of millimeter wavelength (MMW) imaging system are under investigation in this study. The Optical Transfer Function (OTF) was measured and simulated in this study. The performance and quality of the MMW imaging system were tested using point source objects and Point Spread Function (PSF) was obtained. The MMW imaging system is composed of large aperture 500 mm spherical mirror, CW MMW source and 8×8 Glow Discharge Detector (GDD) Focal Plane Array (FPA). In order to investigate the above optical parameters a diagonal mirror was used in order to allow vertically placing of objects rather than horizontally. In order to avoid stray light, absorber materials were placed around the quasi-optic set-up. Special metal resolution charts and point source objects were manufactured and imaged. The influence of the diffraction has been taken care in the calculations and simulations. The experimental results showed very good agreement with the simulations and calculations results.

اللغة الأصليةالإنجليزيّة
عنوان منشور المضيف2011 IEEE International Conference on Microwaves, Communications, Antennas and Electronic Systems, COMCAS 2011
المعرِّفات الرقمية للأشياء
حالة النشرنُشِر - 2011
الحدث2011 IEEE International Conference on Microwaves, Communications, Antennas and Electronic Systems, COMCAS 2011 - Tel Aviv, إسرائيل
المدة: ٧ نوفمبر ٢٠١١٩ نوفمبر ٢٠١١

سلسلة المنشورات

الاسم2011 IEEE International Conference on Microwaves, Communications, Antennas and Electronic Systems, COMCAS 2011

!!Conference

!!Conference2011 IEEE International Conference on Microwaves, Communications, Antennas and Electronic Systems, COMCAS 2011
الدولة/الإقليمإسرائيل
المدينةTel Aviv
المدة٧/١١/١١٩/١١/١١