ملخص
In this paper, a method of designing an optimally arranged solar array for converterless matching to a known linear load is proposed and compared to the classical Maximum Power Point Tracking method. Long-time performance of both methods is examined for three common types of loads under real weather conditions. Test results indicate that only in case of a pure resistive load the Maximum Power Point Tracking-based solar system advantage is undisputed. In case of a load represented by a voltage source with internal resistance, the long term energy productions of the system employing a practical Maximum Power Point Tracking operated converter is on a par or lower than the converterless system energy yield.
| اللغة الأصلية | الإنجليزيّة |
|---|---|
| الصفحات (من إلى) | 11-17 |
| عدد الصفحات | 7 |
| دورية | Renewable and Sustainable Energy Reviews |
| مستوى الصوت | 19 |
| المعرِّفات الرقمية للأشياء | |
| حالة النشر | نُشِر - 2013 |