تخطي إلى التنقل الرئيسي تخطي إلى البحث تخطي إلى المحتوى الرئيسي

Feedback isolation by piezoelectric transformers: Comparison of amplitude to frequency modulation

نتاج البحث: فصل من :كتاب / تقرير / مؤتمرمنشور من مؤتمرمراجعة النظراء

18 اقتباسات (Scopus)

ملخص

Signal isolation is needed in power electronics systems that include separate primary and secondary 'grounds'. The feasibility of using a piezoelectric transformer (PT) as a galvanic barrier was investigated in this study theoretically and experimentally. The research included the issues of drive, demodulation, bandwidth, and common mode rejection. In particular, two types of excitation signals were compared: amplitude modulated and frequency modulated. The frequency response of the piezoelectric isolator was studied by small signal envelope simulation using ORCAD/PSPICE as well as experimentally. It is concluded that the FM approach offers a larger BW but the AM scheme seems to be easier to implement.

اللغة الأصليةالإنجليزيّة
عنوان منشور المضيف2004 IEEE 35th Annual Power Electronics Specialists Conference, PESC04
الصفحات1834-1840
عدد الصفحات7
المعرِّفات الرقمية للأشياء
حالة النشرنُشِر - 2004
منشور خارجيًانعم
الحدث2004 IEEE 35th Annual Power Electronics Specialists Conference, PESC04 - Aachen, ألمانيا
المدة: 20 يونيو 200425 يونيو 2004

سلسلة المنشورات

الاسمPESC Record - IEEE Annual Power Electronics Specialists Conference
مستوى الصوت3
رقم المعيار الدولي للدوريات (المطبوع)0275-9306

!!Conference

!!Conference2004 IEEE 35th Annual Power Electronics Specialists Conference, PESC04
الدولة/الإقليمألمانيا
المدينةAachen
المدة20/06/0425/06/04

بصمة

أدرس بدقة موضوعات البحث “Feedback isolation by piezoelectric transformers: Comparison of amplitude to frequency modulation'. فهما يشكلان معًا بصمة فريدة.

قم بذكر هذا