ملخص
We present simulations results and experimental evidence of radiation energy extraction efficiency enhancement by use of pre-bunching in a free electron maser (FEM). This enhancement is attained by locking the oscillator to operate at a distinct resonator eigen frequency (longitudinal mode) which is different from the maximum-gain frequency of the free running oscillator. The mode selection is accomplished by means of pre-bunching at the desired eigen frequency. It was shown that maximum extraction efficiency is obtained if the dominant resonator mode (obtained by pre-bunching at that frequency) is the one having the lowest eigen frequency under the net gain larger than unity curve (which is below the maximum gain eigen-frequency mode that would normally dominate in a free running oscillator). The numerical simulations predict that it should be possible to obtain a basic extraction efficiency enhancement of the oscillator of 50%. Experimental results so far have shown an improvement of about 30%.
| اللغة الأصلية | الإنجليزيّة |
|---|---|
| الصفحات (من إلى) | 107-110 |
| عدد الصفحات | 4 |
| دورية | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
| مستوى الصوت | 429 |
| رقم الإصدار | 1 |
| المعرِّفات الرقمية للأشياء | |
| حالة النشر | نُشِر - يونيو 1999 |
| الحدث | Proceedings of the 1998 20th International Free Electron Laser Conference and 5th FEL User Workshop - Williamsburg, VA, USA المدة: 16 أغسطس 1998 → 21 أغسطس 1998 |
بصمة
أدرس بدقة موضوعات البحث “Efficiency enhancement of a pre-bunched free-electron maser oscillator by locking to a single eigen frequency of the resonator'. فهما يشكلان معًا بصمة فريدة.قم بذكر هذا
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver