تخطي إلى التنقل الرئيسي تخطي إلى البحث تخطي إلى المحتوى الرئيسي

Anxiety and pain perception using a speculum-free eyelid retraction technique for intravitreal injection

  • Lauren M Wasser
  • , Eduardo Roditi
  • , Adina R Weiss
  • , Yishay Weill
  • , Meni Koslowsky
  • , David Zadok
  • , Joel Hanhart
  • , Itay Magal

نتاج البحث: نشر في مجلةمقالةمراجعة النظراء

9 اقتباسات (Scopus)

ملخص

PURPOSE: This study compared pain and anxiety levels in individuals receiving intravitreal injections (IVIs) using a speculum-free injection technique, the lid splinting eyelid retraction technique, or using a speculum.

METHODS: This was a prospective study of individuals receiving IVI at a single tertiary care medical center who responded to a questionnaire and visual analog scale (VAS) between December 2019 and January 2020. In one group, a speculum was used prior to injection, whereas in the other group, a speculum-free injection technique was used.

RESULTS: A total of 108 individuals were included in this study: 54 received IVI with the speculum-free lid splinting eyelid retraction technique and 54 received IVI with a speculum. A correlation between pain and anxiety was demonstrated in the control group (p-value < 0.01); however, in the speculum-free group, this correlation was lower and not significant. When comparing pain and anxiety between the study groups, lower median pain (Mood's: Z = 5.378, p-value < 0.001) and lower anxiety (Mood's: Z = 2.108, p-value = 0.035) scores were demonstrated in the speculum-free group than in the control group. The distribution of pain scores was significantly different between the study groups (Kolmogorov-Smirnov: D = 0.518, p-value < 0.001), and trending differences in anxiety between the groups were observed (Kolmogorov-Smirnov: D = 0.259, p-value = 0.053).

CONCLUSION: The lid splinting eyelid retraction technique, a speculum-free technique, was associated with less anxiety and pain in patients than the use of a speculum. As IVI often involves repeated treatment, identifying modifiable factors that may relieve anxiety and pain is of utmost importance.

اللغة الأصليةالإنجليزيّة
الصفحات (من إلى)2023-2028
عدد الصفحات6
دوريةGraefe's Archive for Clinical and Experimental Ophthalmology
مستوى الصوت260
رقم الإصدار6
المعرِّفات الرقمية للأشياء
حالة النشرنُشِر - يونيو 2022

بصمة

أدرس بدقة موضوعات البحث “Anxiety and pain perception using a speculum-free eyelid retraction technique for intravitreal injection'. فهما يشكلان معًا بصمة فريدة.

قم بذكر هذا