We evaluated the long-term angiographic outcome of balloon angioplasty by comparing original and follow-up target coronary narrowing. Rather than using restenosis to determine outcome, as in most angioplasty studies, we took an unusual approach and analyzed outcome in terms that are commonly used in progression and regression studies after medical interventions. Quantitative angiographic measurements were undertaken in 315 narrowings with an initial diameter stenosis <90% before and after angioplasty and at follow- up. Angiographic deterioration (>10% increase in follow-up diameter stenosis) was identified in 44 (14%) narrowings. Angiographic deterioration was not influenced by age, sex, risk factors, lipid profile, or the indication for angioplasty. Deterioration was also not predicted by the severity, length, or the location of the narrowing. The deteriorating narrowings had a higher recoil after dilatation compared with narrowings with angiographic improvement (21% ± 31% vs 12% ± 17%, p = 0.006); the residual stenosis after angioplasty was therefore higher. The late loss was also significantly increased compared with narrowings with angiographic improvement (65% ± 26% vs 8% ± 24%, p < 0.001). We conclude that the incidence of angiographic deterioration of coronary disease as a result of restenosis is uncommon but not negligible. Interventional cardiologists should resist the temptation to dilate mild, silent coronary narrowings because the procedure might have an unfavorable angiographic (and probably clinical) effect.

اللغة الأصليةالإنجليزيّة
الصفحات (من إلى)575-579
عدد الصفحات5
دوريةAmerican Heart Journal
مستوى الصوت133
رقم الإصدار5
المعرِّفات الرقمية للأشياء
حالة النشرنُشِر - 1997
منشور خارجيًانعم

بصمة

أدرس بدقة موضوعات البحث “Angiographic deterioration of target coronary artery narrowing as a result of percutaneous balloon angioplasty'. فهما يشكلان معًا بصمة فريدة.

قم بذكر هذا